카테고리 없음

Notifier Fire Warden 50 User Manual

fremcalbinaperna 2021. 5. 27. 21:51
Notifier
Advertising

DN-6995:C • 12/07/2011 — Page 1 of 2

  • Fire Alarm Control Panels; Fire Alarm Peripherals; Integration & Graphics; NOTIFIER Network; Public Address & Voice Alarm; Notification Appliances.
  • Read More of 'Notifier takes up residence at Elmbridge Village' Ageas Hilton top-scores with Notifier by Honeywell fire protection Hilton at the Ageas Bowl (the home of Hampshire cricket ) choose Notifier ID 3000, Honeywell Voice Alarm, FAAST Aspiration, EVCS and Paging Systems.
  • FireWarden-100-2(E) Rev 3. General The Notifier FireWarden-100-2 Rev 3 (NFW2-100) with Version 5.0 firmware is a combination FACP (Fire Alarm Control Panel.
  • Notifier Firewarden 50 Installation Manual - Lib a4423d Let's read Notifier Firewarden 50 Installation Manual! We will often find out this sentence everywhere. When still being a kid, mom used to order us to always read, so did the teacher. Some books are fully read in a week and we need the obligation to support reading. What about now?
  • May 06, 2013  Notifier Firewarden-100-2 User Manual DOWNLOAD HERE. Download the Official User Manual This is it, you have found the Official User Manual for your product.
  • Jun 04, 2014 Notifier firewarden 100 2 user manual Slideshare uses cookies to improve functionality and performance, and to provide you with relevant advertising. If you continue browsing the site, you agree to the use of cookies on this website.

NP-100(A) Series

Addressable Photoelectric Detectors
for the FireWarden Series

Addressable

DN-6995:C • A1-320

An automatic fire alarm system–typically made up of smoke detectors, heat detectors, manual pull stations, audible warning devices, and a fire alarm control panel with remote notification capability–can provide early warning of a developing fire. Such a system, however, does not assure protection against property damage or loss of life.

General

The

NP-100(A), NP-100T(A) and NP-100R(A) addressable,

low-profile plug-in photoelectric detectors use a state-of-the-

art photoelectric sensing chamber with communications to

provide open area protection and are used exclusively with

NOTIFIER’s

FireWarden Series (FireWarden-100-2 and Fire-

Warden-50) and

Spartan (NSP-25) Addressable Fire Alarm

Control Panels (FACPs). The

NP-100T(A) adds thermal sen-

sors that will alarm at a fixed temperature of 135°F (57°C).

Since these detectors are addressable, they will help emer-

gency personnel quickly locate a fire during its early stages,

potentially saving precious rescue time while also reducing

property damage. Two LEDs on each sensor light to provide a

local, visible sensor indication. Remote LED annunciator capa-

bility is available as an optional accessory, PN RA100Z(A).

The

NP-100R(A) is a remote test capable detector for use with

DNR(A)/DNRW duct smoke detector housings.

Features

SLC loop
• Two-wire loop connection.
• Unit uses base for wiring.
Addressing
• Addressable by device.
• Rotary, decimal addressing: 01 – 99 with FireWarden-100-2

and NSP-25, and 01 – 50 with FireWarden-50.

Architecture
• Unique single-source, dual-chamber design to respond

quickly and dependably to a broad range of fires.

• Sleek, low-profile design.
• Integral communications and built-in type identification.
• Built-in tamper-resistant feature.
• Removable cover and insect-resistant screen for simple

field cleaning.

Operation
• Withstands air velocities up to 4,000 feet-per-minute (20 m/

sec.) without triggering a false alarm.

• Factory preset at 1.5% nominal sensitivity for panel alarm

threshold level.

• Visible LED “blinks” when the unit is addressed (communi-

cating with the fire panel) and latches on in alarm.

Mechanicals
• Sealed against back pressure.
• Direct surface mounting or electrical box mounting.
• Mounts to: single-gang box, 3.5' (8.89 cm) or 4.0' (10.16

cm) octagonal box, or 4.0' (10.16 cm) square electrical box
(using a plaster ring — included).

Other system features
• Fully coated circuit boards and superior RF/transient pro-

tection.

• 94-V0 plastic flammability rating.
• Low standby current.
Options
• Remote LED output connection, PN RA100Z(A).

Applications

Use photoelectric detectors in life-safety applications to pro-

vide a broad range of fire-sensing capability, especially where

smoldering fires are anticipated. Ionization detectors are often

better than photoelectric detectors at sensing fast, flaming

fires.

Construction

These detectors are constructed of off-white fire resistant plas-

tic. NP-100(A) series plug-in, low-profile smoke detectors are

designed to commercial standards and offer an attractive

appearance.

Installation

NP-100(A) series plug-in detectors use a detachable mounting

base to simplify installation, service and maintenance.
Mount base (all base types) on an electrical backbox which is

at least 1.5' (3.81 cm) deep. For a chart of compatible junction

Notifier Fire Warden 50 User Manual

boxes, see DN-60054.

NOTE: Because of the inherent supervision provided by the SLC
loop, end-of-line resistors are not required. Wiring “T-taps” or
branches are permitted for Style 4 (Class B) wiring. NP-100R(A)
mounts in a DNR(A)/DNRW duct detector housing.

Operation

Each NP-100(A) series detector uses one of 99 possible

addresses on the FireWarden-100-2 and NSP-25, or one of 50

possible addresses on the FireWarden-50 Signaling Line Cir-

cuit (SLC). It responds to regular polls from the system and

reports its type and status.
The addressable photoelectric sensor in the NP-100(A) series

has a unique unipolar chamberthat responds quickly and uni-

formly to a broad range of smoke conditions. It can withstand

wind gusts up to 4,000 feet-per-minute (20 m/sec.) without

sending an alarm level signal. Because of its unipolar cham-

ber, the NP-100(A) series is approximately two times more

responsive than most photoelectric sensors. This makes it a

more stable detector.

NP-100(A) in B210LP(A) Base

B

210

-2

9

51.j

pg

Advertising

Notifier Fire Systems

Popular Brands

Notifier Fire Panel Manual

Popular manuals